Bio safety Cabinet Class II Type A2
Minimum Order Quantity: 1 Piece
Product Brochure
Brand | V PENTA INDUSTRY |
Class | Class II |
Product Type | Type A2 |
Nominal Size | 4 ft |
Model | V PENTA BSC II A2 |
Lighting Type | UV light |
Power | 230 V AC, 50Hz |
Usage/Application | Type A2 cabinets may be used with biological agents treated with toxic chemicals and radio nuclides |
Technical Specifications of Biological Safety Cabinet Class II Type A2: Type A2 cabinets are sometimes referred to as “total exhaust”. This type of unit ,
70% of the air volume is re- circulated and 30% exhausted through Virus burn out system
Has all contaminated ducts and plenums under negative pressure, or surrounded by Directly exhausted negative pressure ducts and plenums(70% re-circulated through the work Area).
Virus Burn Out fitted with exhaust and ULFA Filter for environment protection.
Fitted with Castor Wheels for easy movability. Front Wheels lockable with brakes. Type A2 cabinets used with biological agents treated with toxic chemicals and radio nuclides required as an adjunct to microbiological studies.
Mini Bio Safety Cabinet
Minimum Order Quantity: 1 Piece
Brand | V PENTA INDUSTRY |
Class | Class II |
Product Type | Type A2 |
Nominal Size | 2 ft |
Model | VPN-BSC II-A2-01 |
Lighting Type | UV Light |
Power | 230V |
Usage/Application | BIOLOGICAL TESTING |
Material | GALVANIZED IRON |
BIO SAFETY CABINET CLASS II A2
The Class II, Type A2 cabinet recirculates approximately 70% of the air through a supply filter, and exhausts approximately 30% of the air through an exhaust filter to the room or through a canopy exhaust connection to a facility exhaust system. HEPA-filtered air descends through the work zone in a vertical, unidirectional flow.
STANDARD FEATURES
v Cabinet made of GI powder coated with inner skin Stainless Steel 304
v Pre-Filter Assemblage for Multi-Dispose particle predominantly in the size range of 5- 20 microns
v HEPA Filter
v Airflow: Designed for 0.45m/s to 0.65 m/s when measure across the entire filters space during the rated life cycle of filters.
v Cleanliness level – class 100
v Fluorescent lamp
v Flow Ratio: Class II Type A2: 70% recirculation 30% Exhaust
v UV- light---- 30watts.
v Front Door: 8MM thickness polycarbonate, vertically sliding, balanced with counter weight.
v Noise level : 65 +/- 5 db
v Vibration level : less than 2.5 um (0.0001)
v Power supply : 230 V Ac
v Stainless steel work table
v Gas cock
v Extra power outlet switch
v Color RAL9002
o 4 x 2 x 2 feet
v Inner Dimension: 610 x 610 x 610 mm (W x D x H)
Overall Dimension : 750 x 850 x 2300 mm (W x D x H)
Additional Information:
- Item Code: VPI-BSC-II-A2-01
- Production Capacity: 4 per Month
- Delivery Time: 3 WEEKS
- Packaging Details: Stretch Film Paking